top of page
Writer's pictureWilson Pipeline

Stainless Steel Tubes and Copper Tubes in Heat Exchanger By wilsonpipeline.com


The high thermal conductivity of copper can not compensate poor thermal conductivity of  organic solid black particles resulting in decrease of heat transfer. Table 1 demonstrates the effect of fouling on thermal resistance of copper and stainless steel tubes with wall thickness of 0.049”.

These calculations show that thermal resistance of stainless steel tubes in the fuel oil preheater will be less then thermal resistance of copper tubes, accumulated coked hard crust deposit of hydrocarbons. The thermal resistance of the tubes is only a part of total resistance of heat transfer, and the effect of fouling and tubing material can be accurately calculated in the process of the thermal design of a heat exchanger.

CopperStainless Steelk- Btu/(hr ft deg. F)225.008.4t/k – (hr sq. ft deg. F)/Btu0.00001810.0004861Fouling 0.0050.005   (per TEMA)Total0.00501810.0054861Per Cent100%109.3%

Where:  t/k-Thermal Resistance of the tubes, t-wall thickness, k- coefficient of thermal conductivity.

Regretfully, TEMA Recommended Good Practice values of Fouling Resistances for Industrial Liquids do not take in consideration effect of tube material.

If the actual Fouling Resistance of # 6 Fuel Oil in the heater made from stainless steel tubing equals to 0.0025, then:Fouling0.0050.0025Total0.00501810.0029861Per Cent100%   40%

The coking of hydrocarbons accelerated at elevated temperature of heating tubes. The evaporation of light hydrocarbon residue fractions definitely accelerates coking.

As a good practice, The Alstrom Corporation recommends to maintain the temperature of heating media about 120 deg. F above the outgoing temperature of the #6 heating oil or less.

For instance, #6 Fuel Oil Outgoing Temperature, deg.FRecommended Temperature of Heating Media, deg.FMaximal Steam Pressure, psig120240101502703018030050220340100250370150

The excessive steam pressure can be used to size temperature regulator.

These recommendations are valid for asphalt and other highly viscous liquids. For instance, heating syrups may result in carmelization of the fluid.

Similar, but in less degree, phenomena occurs in shell & tube heat exchangers for water heating. Indeed, copper tubes are oxidized, resulting in fast accumulation of solid deposits.

Copper has poor mechanical properties, particularly on elevated temperatures common in heat transfer. 

Tube-to-tube sheet joint of copper tubes with other materials commonly made by tube expansion. ASME Boiler & Pressure Vessel Code estimates efficiency if expanded joint 60-65%. Stainless steel tubes can be not only expanded but also seal welded to the tubesheet, resulting in 100% joint efficiency.  In this case, according to the Standard for Power Plant Heat Exchangers of Heat Exchange Institute, the metal temperature of welded joint can reach the maximum value permitted by ASME Code.

After introducing 316 stainless steel tubes as a standard material of fabrication shell & tube heat exchangers and using expansion-welding technology The Alstrom Corporation was never reported about tube damage or leak in the tube-to-tubesheet joint.

0 views0 comments

Recent Posts

See All

Knowledge About Steel Elbow

Elbows 45° - 90° - 180° LR/SR The function of a elbow is to change direction or flow in a piping system. By default, there are 5...

Knowledge About Buttweld Fittings

Buttweld Fittings general A pipe fitting is defined as a part used in a piping system, for changing direction, branching or for change of...

List of Chemical Elements

Flange Fittings&Pipes origin supplier from china Wilson Pipeline WhatsApp+8618632758880 sales@wilsonpipeline.com www.wilsonpipeline.com

Comments


bottom of page